Postby Hasbeen » 27 May 2017 01:04
I have twin 18" fans on the 8 set up as BenTens [Got mine from Robsport. They recommend a fused line from the ignition switch but i took direct fused power from battery so it may work independent of ignition].
This gave me a funny problem, apart from occasionally running too long after switching the engine off & flattening the battery.
When making a short stop for fuel for example, with the engine stopped & no coolant circulation, the heat sink from the engine would bring the water in the top of the radiator up to switch on temperature.
The 2 fans drew 36 amps, so when running did not leave enough power available from the battery to start the high compression 4.6L V8. I had to install a push button switch, set up to be always on, [to avoid an old forgetful fool turning them off & leaving them off] & push & hold pushed to turn off, to cut them out, to be able to start the thing.
On the viscous fan, my 7, with a new radiator & viscous fan [fitted when the aircon went in], can run all day, hard or in heavy traffic, on 100+F days with the aircon running flat out, & never gets above 3/16 on the gauge. The cooling system is entirely adequate, if in good condition.
Hasbeen